1. SCOPE
 
1.1 This Standard defines requirements and test methods for ligature resistant trim on bored locks and
mortise locks. These requirements apply to the exposed parts of the lockset on the face of the door in the
closed position only.
 
1.2 Tests described in this Standard are performed under laboratory conditions. In actual usage, results
vary because of installation, maintenance and environmental conditions.
 
1.3 Level Qualifications. Manufacturers shall indicate the Level that their trim meets (i.e. Level A, B or C)
for each side of the door. The product Level is established based on testing the Ligature Resistant Trim to
the requirements established in Section 4. The inside and outside trim shall be evaluated and rated
individually unless they are identical; it is acceptable for only one side to meet a level.
 
Approved December 22, 2016
Previous Article ANSI/BHMA A156.32 Integrated Door Opening Assemblies
Next Article ANSI/BHMA A156.36 Auxiliary Locks

Please login or register to post comments.

Search BHMA Certified® Products

For complete listings of BHMA Certified® Products, view the BHMA Certified® Products Directory (CPD). The listings in this directory are performance-oriented standards having cycle, operational, strength, security, and finish test requirements.

Search Now

Get Certified

Participate in the BHMA® Certification Program by voluntarily submitting a hardware product to independent laboratory testing to confirm that it fully meets the criteria of the appropriate ANSI/BHMA® standard.  This industry-wide certification program does not call for a manufacturer to be a BHMA® member in order to certify its products.

Learn More