A156.3 – Exit Devices (ANSI Approved November 2020) Friday, November 6, 2020 1.1 Removed self-latching flush bolts from the scope (covered in A156.16) 2.7 Added language to allow use of optional brackets 3.1 Clarified definition for actuating bar surface 4.0 Clarified Types excluded from the optional Security Test, added language for utilizing suffix “S” and added Types 29 and 30 for exit devices on glass doors 7. Added test fixtures from appendix C to section 7 8.2 Removed language “Portions of the actuating bar which are below 30 in. (750mm) and more than 48 in. (1250mm) above the floor when installed per the manufacturer’s templating are exempt from this requirement” as it does not align with code requirements for the hardware to be mounted between 34” and 48” above finished floor (AFF) 9.2.3 Added language for single motion to egress 9.3 Clarified sequence of testing 9.3.2 Added language, “failure of mullion does not constitute failure of the device” 9.3 Increased load requirement for grade one from 400lbs to 600 lbs. on the outside pull test 14.2 Removed Grade 1 carry open bar 15 Added optional security test Appendix A-5 Clarified language on fusible fire pins Appendix A-8 Added Cycle Test information Appendix B Added Type 29 and Type 30, Glass Door Exit Device –top latching and bottom latching Appendix C Removed Figure 4 Dent Depth Measuring Device Appendix C Added Bracket Diagram Previous Article A156.9 – Cabinet Hardware (ANSI Approved November 2020) Next Article Committee Spotlight: Codes, Government and Industry Affairs Committee Please login or register to post comments.